Inquire nowAll verifications of electric safety provided for by 17th Edition.
Advanced Loop Verification of magnetothermal protections, fuses and cable sizes.
Measurement of electric parameters insingle- phase installations (V,I, W, VAR, VA, PF).
Test of RCDs type A, AC, B up to 1A, also with separate clamp jaws with test current up to 10A (with optional accessory RCDX10).
Measurement of insulation resistance.
Measurement of continuity of protection conductors.
Verification of phase sequence (SEQ) and leakage currents.
Measurement of environmental paramemeters with external probes.
It is used for checking the safety of private and industrial electric systems (17th edition). Thanks to its building characteristics, the type of setting and the multiple applications as regards the documentation it is capable of producing, this device can satisfy even the most demanding technician and the most rigorous verifier.
Its TFT colour display with capacitive touch-screen allows using this device in a completely new manner.
COMBITOUCH makes available on its display all possible variables to obtain a perfect measurement; your task will only be to “touch” what you really want to measure: then, simply leave the rest to COMBITOUCH's micro-processor.
The device complies with all requirements as regards the safety of electric systems: test of RCDs type A, AC also up to 1000 mA and type B insulation continuity earth resistance tests directly on the power outlet without causing the RCDs’ tripping.
With the appropriate programming guided by the touch-screen system, this device can test the interruption power, tripping currents, I2t relevant to magneto-thermal switches (MCB) with curves B, C, D, K and fuses type gG and aM Combined with optional clamp HT96U it is capable to carry out and record measurements of leakage current, power, cosphi, harmonics, THD% and frequency.
Functions | |
AUTO test (Non-trip ground resistance, RCD, Insulation) in sequence | |
TRMS | |
L/N-PE Insulation with test voltages 50, 100, 250, 500, 1000V | |
Continuity of protective conductors with 200mA | |
Tripping time and current of RCDs type B, A, AC Standard, Selective and Delayed up to 1A | |
Tripping time and current of RCDs with separate clamp jaws type B, A, AC Standard, Selective and Delayed up to 10A | With optional accessory RCDX10 |
Non-trip earth resistance | |
Loop/Line impedance, Phase-Phase, Phase-Neutral, Phase-PE | |
Loop/Line impedance Phase-Phase, Phase-Neutral, Phase-PE with high resolution (0.1mΩ) | With optional accessory IMP57 |
Measurement of percentage voltage drop on the line | |
Contact voltage | |
Phase sequence | |
Leakage current with optional clamp meter | |
Measurement of Voltage, Current, Active, Reactive, Apparent Power | |
Measurement of Cosphi, Power Factor | |
Voltage and current harmonics up to the 49th with THD | Up to 25th |
Protection category | CAT IV 300V |
Measurement of environmental parameters (°C,°F, %RH, Lux) | |
Test with remote lead | PR400 |
Help on line on the display | |
Internal memory for measured data saving | |
Optical/USB serial port for PC connection | |
Integrated WiFi connection and compatibility with HTANALYSIS App | |
Size (LxWx H) (mm) | 222x162x57 |
Weight in grams (batteries included) | 1200 |
This device has been devised for use together with optional accessories which widen its operating fields: e.g. RCDX10 for testing RCDs with separate jaws up to 10A.
Cutting-edge management of measurement with indication, at the end of each safety test, of compliance or non-compliance with requirements with simple symbols OK o NOT OK.
Finally, thanks to the brand new HTAnalysis App, free to download for iOS and Android systems, COMBITOUCH is capable of transferring measured and recorded data onto tablets and smartphones, thus giving the operator the possibility to customize and share through HtCloud the result of their tests.
Guidelines | |
17th edition | |
CEI 64-8 | |
CEI 64-8 612.2 | |
CEI 64-8 612.3 .4 .5 | |
CEI 64-8 612.6.1 | |
CEI 64-8 612.6.2 | |
CEI 64-8 612.6.3 | |
CE MARK | |
DPR 462 del 22/10/2001 | |
EMC: IEC/EN61326 | |
EN50522 | |
EN61008 | |
IEC/EN6090-0 | |
IEC/EN61010-1 | |
IEC/EN61557-1 | |
IEC/EN61557-2 | |
IEC/EN61557-3 | |
IEC/EN61557-4 | |
IEC/EN61557-6 | |
IEC/EN61557-7 | |
LVD 2014/35/EU | |
UNE20460 | |
VDE 0100 |