IDEM’s magnetic, non-contact safety interlocks are designed to conform to IEC 60947-5-3 and be used as directed by ISO12100, ISO14121 and ISO EN14119.
They feature magnet and reed technology, providing a high tolerance to misalignment and extreme temperatures.
The mechanical operations means the contacts are volt free with a high power switching capability of 1A or 2A ac/dc.
They are suitable for hinged, sliding or removable guard applications and can connect to most safety relays to provide a higher level of functional safety.
Features | |
Housing/Fixing: Industry Standard, Slim Line | |
Material: High spec polyester, ideal for exposure to chemical cleaning agents | |
Contacts: Up to 2 N/C safety outputs and 1 N/O auxiliary output. | |
Sensing Distance: Wide 12mm operation | |
Ingress Protection: IP67 and IP69K | |
Operating Temperature: -25c to +80c | |
Connection: Pre-Wired or M12 Quick Connect |