Flow transmitter / flow switch for general industrial and for hygienic and aseptic applications
Inquire now
Advantages |
Application |
FU4SK suitable for general applications in
FU4LK suitable for general applications in
The device is an electronic flow resp. temperature switch for monitoring, control and continuous measurement of flow and temperatures in liquids.
A high variety of versions of process connections and electronic types allows the use for a wide range of applications, also for demanding measuring requirements.
The process connection of the FU4LK with metallic sealing has been specifically designed for the hygienic, dead-space and elastomer-free process adaption.
Due to its high accuracy and the digital adjustability by RS485 Modbus®-RTU or IO-Link® the device can be suited to a wide variety of applications.
The robust design and the high-quality workmanship turns the device into a very high quality product, which even the most adverse environmental conditions cannot affect, whether the lowest temperatures when used outdoors, extreme shock and vibration stress or aggressive media.
A captive laser marking of the type label ensures the identifiability throughout the entire lifetime of the device.
Obviously is the optional marking of a measurement point designation resp. TAG, a customer label or of a neutral type label, of course also per laser marking.
A LABS- resp. silicone-free version, a factory calibration with calibration certificate and a customer specific configuration resp. preset is also optionally available like a material test certificate EN10204 3.1 or a factory certifications for drink water resp. food suitability.
Customer specific special versions can be realized short-term on request, e.g. special designs for the process connection or other process materials.
Technichal data |
Measuring range
Measuring principle Calorimetric flow measurement
Nominal measuring range 3…300 cm/s
Output type V – RS485 Modbus®-RTU
Interface RS485, bidirectional / Modbus®-RTU / 9600 Baud (4800…38400 Baud)
Time behavior Flow: T90 ≤ 6s / ton ≤ 10s
Temperature: T90 ≤ 4s / ton ≤ 2s
Output type L – IO-Link®
Interface IO-Link® V1.1 / Com2 (38400 Baud)
Analogue output 0…20mA: 0…20,5mA / ≤ 0,05mA / ≤ 22mA / dI ≤ 1µA
4…20mA: 3,8…20,5mA / ≥ 3,6mA / ≤ 22mA / dI ≤ 1µA
Switch output 2x PP (Push-Pull), switch to +L/-L
Output Uout ≤ 0,2V, ≥ Us – 2V / Iout 0…200mA (current limited ≤ 450mA, short circuit protected)
Time behavior Flow: T90 ≤ 6s / ton ≤ 10s
Temperature: T90 ≤ 4s / ton ≤ 2s
Auxiliary power Supply voltage Us polarity protected Type V – RS485 Modbus®-RTU: 6…35VDC
Type L – IO-Link®: 9…35VDC, without IO-Link® / 18…30VDC, with IO-Link®
Measuring accuracy Accuracy Flow: ≤ ±5% Measuring end value (5…100cm/s) / (-20°C…+85°C) / ≤ ±10% Measuring end value (100…175cm/s) / (-20°C…+85°C)
Temperature: ≤ ±1,5K (≥ 20cm/s)
Long term drift Flow: ≤ ±10% of measuring value / year (-20°C…+85°C)
Temperature deviation Flow: ≤ ±0,4cm/s / K (-20°C…+85°C)
Process conditions
Process temperature -20°C...+110°C, +140°C/1h
Process pressure ≤ 40 bar
Environmental conditions
Environmental temperature -20°C...+100°C
Protection level IP69K/IP67 (EN/IEC 60529)
MTTF 463 years