Hit Enter to Search
Gas Sense GS-220.BC.V -1

Gas Sense GS-220.BC.V -1

Addressable gas detector for combustible gases

Inquire now
  • Gas detectors GS-220.BC.V are monitoring levels of hydrocarbon gases, organic solvents and their vapors, hydrogen, natural gas, LPG ​​and other combustible gases.

  • Different principles of detection with catalytic, semiconductor or electrochemical sensor elements are used.

  • Reliable operation of the detector is ensured by the self-diagnostic function, which constantly monitors the condition of the sensor and signal lines and alerts in case of fault.

  • Sensor calibration is done remotely with magnetic key without opening the enclosure that facilitates periodic inspection and maintenance.

  • Gas sensors GS-220.BC.V are in a metal housing with IP 65.


Application
Analogue gas detector GS-220.BC.V is intended for detection and measurement of combustible gases.
Detected gases Formula Measuring range Order code
METHANE   0 - 100% LEL GS-220.BC.V.CH4.100
PROPANE   0 - 100% LEL GS-220.BC.V.PRO.100
N-BUTANE   0 - 100% LEL GS-220.BC.V.PRO.100
N-PENTANE   0 - 100% LEL GS-220.BC.V.PEN.100
N-HEXANE   0 - 100% LEL GS-220.BC.V.HEX.100
N-HEPTANE   0 - 100% LEL GS-220.BC.V.HEP.100
N-OCTANE   0 - 100% LEL GS-220.BC.V.OCT.100
METHANOL   0 - 100% LEL GS-220.BC.V.MNL.100
ETHANOL   0 - 100% LEL GS-220.BC.V.ETL.100
ISO-PROPANOL   0 - 100% LEL GS-220.BC.V.IPR.100
ACETONE   0 - 100% LEL GS-220.BC.V.ACE.100
METHYL ETHYL KETONE   0 - 100% LEL GS-220.BC.V.MEK.100
TOLUENE   0 - 100% LEL GS-220.BC.V.TOL.100
ETHYL ACETATE   0 - 100% LEL GS-220.BC.V.EAC.100
HYDROGEN   0 - 100% LEL GS-220.BC.V.HYD.100
AMMONIA (LEL)   0 - 100% LEL GS-220.BC.V.AMM.100L
UNLEADED PETROL   0 - 100% LEL GS-220.BC.V.UPT.100
ETHYLENE   0 - 100% LEL GS-220.BC.V.ETH.100
Sensors for gases, not listed in the table are made with preliminary order.
TECHNICAL SPECIFICATIONS
  • measurement principle: semiconductor, catalytic, electrochemical

  • measuring range: 0–100% LEL

  • output signal: 4-20mA

  • working voltage: 12V÷30VDC

  • power consumption: < 2W

  • weght: 0,520 kg

  • sizes: 155 ? 95 ? 48 mm

  • enclosure material: aluminium

  • ingress protection: IP65

  • cable glands: 1/2/3 - ?16/M20

  • working temperature: -20 ÷ + 50 ºC

  • humidity: 30 ÷ 90% RH

  • pressure: 1 bar ± 20%

  • runtime: till 5 years under standard conditions for semiconductor and catalityc sensors

  • meets the requirements of EN 50270

  • ATEX certification:

  • Created with GIMP II 2G Ex ma (ib) e IIC T4 Gb

  • II 2D Ex to(ib)ma IIIC T135C IP65 Db