Application description |
The level monitor Mycrocont MCN is used for easy and reliable level monitoring of liquids or solids. In addition to aqueous media, also e.g. oils, honey, chocolate, Emulsions and various fine-grained materials such as grain, sugar, milk powder, etc. can be recorded. Because of the elastomer-free seal between the tip and sleeve the Mycrocont MCN can also be used for hygienic applications. The medium can be balanced via DIP switches or an optional software??. The control software can detect differences in media and the switching characteristics of this situation can be matched exactly. Suitable in the appropriate configuration for media with εr> 2, including chocolate, honey, vegetable oil, etc., and all aqueous media.
Technichal data |
Process connection G1 / 2 "hygienic
Output signal PNP, NPN or push-pull switchable
Materials (in process PB) PEEK * 1
Materials Housing parts 316L
Protection class IP67 according to DIN EN 60529
Switch-on delay <0.3 sec
Response dynamics <0.2sec
Supply voltage Ub = 24V (12 ... 32VDC)
Permissible load 0ohm, 24VDC, 100mA
Setting by PC software "MCN SOFT"
Electrical connection M12 plug 5-pin. Pin 2 + 5 milled, for data communication