  • Digital pressure switch and pressure transmitters for hygienic

  • applications - Latest generation with a large display, analog and 4 pnp switching outputs


Advantages
  • Wide range of applications

  • Finely graded measuring ranges from 100 mbar up to 25 bar

  • Wide process temperature range –20°C to +150°C

  • Various hygienic and aseptic process connections

  • High protection class IP65 / IP67

  • Wide environmental temperature range –20°C to +70°C

  • Metallic front-flush EHEDG conformal diaphragm

  • Highest accuracy – characteristic deviation to ≤ 0,15% of measuring range

  • Integrated evaluation electronic: Graphic display, keyboard; 4x PNP switch output; 1x current output 0/4…20mA – voltage output 0…10V; Measure data memory for more than 500.000 measuring values; Battery powered data logger function ; Bluetooth-Interface; Connector plug M12

  • High operating comfort: Enclosure and display rotatable for optimal operability in each installation position; High contrast high brightness TFT-LCD display for best readability; 3-key operation without additional assistance with tactile feedback; Easy handling by clear menu navigation; Extensive diagnostic functions for system analysis

Application description

The device is an electronic pressure transmitter / pressure switch for monitoring, control as well as continuous measurement of pressures in gases, vapors, liquids and dusts.

Due to the device construction with measuring ranges from -1 bar to 25 bar (gauge), measuring ranges from 0 bar to 25 bar (absolute), measuring spans from 100 mbar to 25 bar, process temperatures from –20°C to +150°C, process material CrNi-steel as well as the availability of a variety of hygienic EHEDG-conformal process connections like thread ISO 228-1 with front-flush O-ring gasket, dairy coupling DIN 11851, Varivent® and DRD the device is especially suitable for the use for food and beverage industry, pharmaceutical industry, biotechnology and sterile process engineering.

The device is suitable for demanding measuring requirements. 

Due to its high accuracy and the high flexibility of configuration, the device can be suited a wide variety of applications.

The device with front-flush diaphragm has been specifically designed for the measurement of viscous, paste-like, adhesive, crystallizing, particle-laden and contaminated media, which would clog the pressure channel of conventional process connections.

Through its optimized design, the front-flush process connection enables the cleanability of the wetted diaphragm to be integrated into the process.

The device is particularly suitable for the special conditions of CIP/SIP cleaning processes, such as chemical stability towards cleaning liquids and high temperatures.

Low-maintenance and trouble-free pressure measurement is thus also guaranteed in critical applications with frequently changing media.

The front-flush diaphragm is completely welded with the process connection and supplied with a positive seal. A reliable, dead-space free sealing between the process connection and the process adapter resp. measuring medium is thus assured.

The robust design and the high-quality workmanship turns the device into a very high quality product, which even the most adverse environmental conditions cannot affect, whether low temperatures when used outdoors, high shock and vibration or aggressive media.

Technical data

Supply voltage:
Setting output 0/4...20 mA: 9..30 VDC, reverse polarity protected
Setting output 0…10 V: 14..30 VDC, reverse polarity protected

Analogue output
Operating range
: current 0…20mA: 0…20,5mA, max. 22mA
current 4…20mA: 3,8…20,5mA, min. 3,6mA, max. 22mA
voltage 0…10V: 0 ... 10,5 V, max. 11 V
Permitted load: current 0…20mA / current 4…20mA: ≤ (US - 9V) / 22mA
voltage 0…10V: ≥ UOut / 3mA
Step response time: ≤ 15 ms (td = 0s)
Start-up time: ≤ 1s
Switch output PNP S1 / S2 / S3 / S4
Function
: PNP switch to +L
Output current: IL 0… ≤ 200mA, current limited, short circuit protected
Step response time: ≤ 25 ms (td = 0s)
Switch cycles: ≥ 100.000.000

Bluetooth Interface
Version
: Bluetooth 2.1 + EDR
Specification: Class 2
Transmit power: ≤ 2,5mW/4dBm
Range: ≤ 10m

Measuring accuracy
Characteristic deviation: ≤ ±0,15% / ±0,5% FS
Long term drift: ≤ ±0,2% FS / year
Temperature deviation: Measuring range ≤ 250 mbar: ≤ ±0,04% FS / K (0…+80°C) / ≤ ±0,06% FS / K (-20…0°C / +80…+150°C)
Measuring range ≥ 400 mbar: ≤ ±0,02% FS / K (0…+80°C) / ≤ ±0,03% FS / K (-20…0°C / +80…+150°C)

Materials

Membrane (process wetted): Steel 1.4435/316L

Process connection (process wetted): Steel 1.4435/316L

Terminal enclosure: CrNi-steel

Control panel surface: PES

Gaskets (process wetted): FPM – fluorelastomere (e.g. Viton®), FDA-listed

EPDM – ethylene-propylene-dienmonomere, FDA-listed

 

Environmental conditions

Environmental temperature: – 20°C...+70°C

Process temperature: – 20°C...+150°C

Process pressure: 100 mbar up to 25 bar depending on type

Protection: IP68 EN/IEC 60529