Pressure switch for supervision of absolute and relative pressures in gases, vapors, liquids and dust
Inquire now
Advantages |
Application description |
Due to the device construction as well as the availability of a variety of hygienic resp. standard process connections the device is especially suitable for the use for hygienic and aseptic applications in food and beverage industry, pharmaceutical industry, biotechnology and sterile process engineering as well as general applications in machinery and plant engineering, air-conditioning and refrigeration plant engineering, hydraulic and pneumatic systems, process industry and environmental technology.
The pressure switch is suitable for demanding measuring requirements.
Due to its high accuracy and the high flexibility of configuration, the device can be suited a wide variety of applications.
The pressure switch with front-flush diaphragm has been specifically designed for the measurement of viscous, paste-like, adhesive, crystallizing, particle-laden and contaminated media, which would clog the pressure channel of conventional process connections.
The front-flush diaphragm is completely welded with the process connection and supplied with a positive seal. A reliable, dead-space free sealing between the process connection and the process adapter resp. measuring medium is thus assured.
The robust design and the high-quality workmanship turns the device into a very high quality product, which even the most adverse environmental conditions cannot affect, whether the lowest temperatures when used outdoors, extreme shock and vibration or aggressive media.
A captive laser marking of the type label ensures the identifiability throughout the entire lifetime of the device. Obviously is the optional marking of a measurement point designation resp. TAG, a customer label or of a neutral type label, of course also per laser marking.
A LABS-free resp. silicone-free version, a factory calibration with calibration certificate and a customer specific configuration resp. preset is also optionally available like a material test certificate EN10204 3.1 or factory certifications for drink water resp. food suitability.
Technische Daten |
Supply voltage: 10,5…35VDC, reverse polarity protected
Supply current: ≤ 60mA Analogue output max. 22,5mA Switch output with no load
2xPNP-switch output
Function: PNP switch to +L
Output current: 0… ≤ 200mA current limited, short circuit protected
Analogue output 4...20mA
Operating range: 3,9…21mA, min. 3,8mA, max. 22mA
Permitted load: ≤ (US - 10,5V) / 22mA
Start-up time: ≤ 1 ms
Measuring accuracy
Characteristic deviation: ≤ ± 0,2% FS
Long term drift: ≤ ± 0,1% FS / year not cumulative
Temperature deviation Zero: ≤ ±0,015% FS / K, max. ±0,75% (-20°C…+80°C); Span: ≤ ±0,015% FS / K, max. ±0,5% (-20°C…+80°C / > 400mbar), max. ±0,8% (-20°C…+80°C / ≤ 400 mbar)
Materials
Diaphragm: (process wetted) Measuring range ≤ 1bar: Ceramic Al2O3 – 99,7% (SIP suitable); Measuring range ≥ 1,6bar: Ceramic Al2O3 – 96% (SIP suitable); Process connection 1/2/4/6/7/N/M/P/L/S/T: Ceramic Al2O3 – 99,9% (CIP/SIP suitable)
Process connection: (process wetted) Steel 1.4404/316L / Steel 1.4571/316Ti
Terminal enclosure: CrNi-steel
Gaskets (process wetted): FPM – fluorelastomere (e.g. Viton®) / EPDM – ethylene-propylene-dienmonomere, FDA-listed / FFKM – perfluorelastomere (e.g. Kalrez®) / FFKM hd – perfluorelastomere high density Environmental conditions
Environmental temperature: – 40°C...+85°C
Process temperature: -40...+100°C (extended -40...+125°C)
Process pressure: – 1 bar ...60 bar (depending on process connection)
Protection: IP65/IP67 EN/IEC 60529