Advantages |
Application description |
Due to the device construction with measuring ranges from -1 bar to 600 bar, gauge, measuring ranges from 1 bar to 40 bar, absolute, measuring spans from 250 mbar to 600 bar, process temperatures from –40°C to +135°C and process materials Al2O3-ceramic / CrNi-steel as well as the availability of industrial standard process connections like thread connection ISO 228-1, EN 837 manometer, thread connection ISO 228-1 (inner thread), thread connection ISO 228-1 (EN 1179-2 E), thread connection ISO 228-1 (inner bore) and thread connection ISO 228-1 (front-flush) the device is especially suitable for the use for machinery and plant engineering, air-conditioning and refrigeration plant engineering, hydraulic and pneumatic systems, process industry, environmental technology and facility and building automation.
The device is suitable for demanding measuring requirements.
Due to its high accuracy and the high flexibility of configuration, the device can be suited a wide variety of applications.
The robust design and the high-quality workmanship turns the device into a very high quality product, which even the most adverse environmental conditions cannot affect, whether the lowest temperatures when used outdoors, extreme shock and vibration or aggressive media.
A captive laser marking of the type label ensures the identifiability throughout the entire lifetime of the device.
Obviously is the optional marking of a measurement point designation resp. TAG, a customer label or of a neutral type label, of course also per laser marking.
A LABS-free resp. silicone-free version, a factory calibration with calibration certificate and a customer specific configuration resp. preset is also optionally available like a material test certificate EN10204 3.1 or factory certifications for drink water resp. food suitability.
Technische Daten |
Supply voltage: 10,5…35VDC, reverse polarity protected
Supply current: ≤ 60mA Analogue output max. 22,5mA Switch output with no load
Switch output S1 / S2
Function: PNP switch to +L
Output current: 0… ≤ 200mA current limited, short circuit protected
Analogue output 4...20mA
Operating range: 3,9…21mA, min. 3,8mA, max. 22mA
Permitted load: ≤ (US - 10,5V) / 22mA
Start-up time: ≤ 1 s
Measurement accuracy
Characteristic deviation: ≤ ± 0,5% FS
Long term drift: ≤ ± 0,2% FS / year not cumulative
Temperature deviation Measuring range 0…250 mbar to 0…2,5 bar: ≤ ±0,05% FS / K / Measuring range 0…4 bar to 0…600 bar: ≤ ±0,04% FS /K
Materials
Diaphragm: (process wetted) Ceramic aluminum oxide Al2O3 – 96%
Process connection: (process wetted) Steel 1.4404/316L / Steel 1.4571/316Ti
Terminal enclosure: CrNi-steel
Gaskets: (process wetted) FPM – fluorelastomere (Viton®) / EPDM – ethylene-propylene-dienmonomere, FDA-listed
Environmental conditions
Environmental temperature: – 40°C...+85°C
Process temperature: – 40...+100°C (extended -40...+135°C)
Process pressure: 0 bar ...600 bar (depending on process connection)
Protection: IP65/IP67 EN/IEC 60529