Advantages: |
Application description |
The Precont® S20 is used in all fields of proceeding and process technique.
The excellent characteristics like pressure strength, high chemical resistance, corrosion protection and insensitivity against temperature shocks allows the use in the hardest applications for the measurement of gases, steams and liquids.
The polysilicone resp. thin-film measurement sensor guarantees highest pressure ranges, good reproduceability and hysteresis, an up to 4 times overload resistance and a good long term stability.
Technical Data: |
4...20mA / mit Display Ausführung A/B 14,5...45 V DC Ex 14,5...30 V DC
0...10V Ausführung E/F/G/H 14,5...45 V DC Ex 14,5...30 V DC
4...20mA / ohne Display Ausführung C/D 10,5...45 V DC Ex 10,5...30 V DC
Profibus PA Ausführung P 9…32 V DC Ex 9...24 V DC
Stromaufnahme:
2-Leiter 4...20 mA ≤ 22 mA PNP-Schaltausgänge im Leerlauf
3-Leiter 0...10 V ≤ 10 mA PNP-Schaltausgänge im Leerlauf
2xPNP-Schaltausgang
Funktion: PNP-schaltend auf +Vs
Ausgangsstrom: ≤ 250 mA strombegrenzt, kurzschlussfest
Messgenauigkeit
Kennlinienabweichung: ≤ ± 0,5% FS
Langzeitdrift: ≤ ± 0,15% FS / Jahr nicht kumulativ
Temperaturabweichung : ≤ ± 0,20% FS / 10 K
Werkstoffe
Membrane: (mediumberührend)
≥ 40 bar Stahl 1.4571 (AISI 316Ti)
< 40 bar Stahl 1.4542 (AISI 630) / 1.4534
Prozessanschluss: Stahl 1.4571 (AISI 316Ti) (mediumberührend)
Anschlussgehäuse: CrNi-Stahl / PBT Polybutylenterephthalat / PP – Polypropylen / POM – Polyoxymethylen (Delrin®)
Dichtungen: (mediumberührend)
FPM – Fluorelastomer (Viton®)
EPDM – Etylen-Propylen-Dienmonomer
CR – Chloroprenkautschuk (Neopren®)
FFKM – Perfluorelastomer (Kalrez®)
NBR – Nitril-Butadien-Kautschuk
Umgebungsbedingungen
Umgebungstemperatur: –40°C ... +85°C
Prozesstemperaturen: –40°C ... +100°C bzw. +125°C
Prozessdruckbereiche: –1 bar ... 1000 bar
Turn-Down: 30:1
Schutzart:
IP67 EN/IEC 60592
IP65 bei Ex-Ausführung