Hit Enter to Search
Precont S30

Precont S30

 With EHEDG process connection for hygienic applications

Inquire now

   


Advantages:
  • High precise pressure measurement -1...25 bar, relative and absolute
  • Front flush metallic membrane with surface roughness Ra < 0,4µm
  • EHEDG conform process connection
  • Up to 4-times overload resistance
  • Process temperatures from -20°C to +150°C
  • Rugged design - maintenance free
  • Electronic rotateable by 330 degree
  • 2-wire 4...20mA or 3-wire 0...10V technology
  • 2 PNP switching outputs
  • 4-digit LED display
  • Fast adjustment by key combination or menue guided adjustment by LED display
  • Password protection
  • Certification for the use in explosive hazardous areas
Application description

The devices of the series Precont® S30 with EHEDG conform process connection for hygienic applications are used for supervision, control and also for continuous measurement of pressures from -1 up to +25 bar in gases, steams, liquids and dusts within closed containers or pipelines at process temperatures from -40°C to +150°C.

 

The pressure sensor Precont® S30 is expecially designed for the requirements in the food and semi-luxory item industy, as well as the pharmaceutical industry and biotechnology. This is especially relavant for the extreme conditions like chemical resistance against cleaning agents as well as insensitiveness against increases temperatures in the case of CIP/SIP cleaning processes.

 

Due to the availability of adapters for the common process connections like varivent or connections acc. to DIN11851 with cone flange with nut groove for pipes acc. to DIN 11850, as well as a suitable weld-in sleeve the pressure transmitter can be installed in nearly hygienic application.

 

The use of a strain gauge with metallic membrane guarantees excellent characteristics like high pressuren and pressure blow strength, high resistance against chemicals and corrosion, very good insensitiveness against temperature shocks and EM interferences, high accuracy and long term stability as well as low temperature sensitiveness.

Technische Daten:

Hilfsenergieversorgung
4...20mA / mit Display Ausführung  A/B 14,5...45 V DC Ex 14,5...30 V DC
0...10V Ausführung  E/F/G/H 14,5...45 V DC Ex 14,5...30 V DC
4...20mA / ohne Display Ausführung C/D 10,5...45 V DC Ex 10,5...30 V DC
Profibus PA Ausführung P 9…32 V DC Ex 9...24 V DC

Stromaufnahme

   2-Leiter 4...20 mA ≤ 22 mA PNP-Schaltausgänge im Leerlauf
   3-Leiter 0...10 V ≤ 10 mA PNP-Schaltausgänge im Leerlauf

2xPNP-Schaltausgang
Funktion
: PNP-schaltend auf +Vs
Ausgangsstrom: ≤ 250 mA strombegrenzt, kurzschlussfest

Messgenauigkeit

Kennlinienabweichung: ≤ ±0,5% FS
Langzeitdrift: ≤ ±0,15% FS  / Jahr nicht kumulativ
Temperaturabweichung : ≤ ±0,20% FS / 10 K

Werkstoffe
Membrane: Stahl 1.4435 (AISI 316L) (mediumberührend)
Prozessanschluss: Stahl 1.4435 (AISI 316L) (mediumberührend)
Anschlussgehäuse: CrNi-Stahl / PBT Polybutylenterephthalat / PP – Polypropylen / POM – Polyoxymethylen (Delrin®)
Dichtungen: (mediumberührend)
   FPM – Fluorelastomer (Viton®)
   EPDM – Etylen-Propylen-Dienmonomer
   CR – Chloroprenkautschuk (Neopren®)
   FFKM – Perfluorelastomer (Kalrez®)
   NBR – Nitril-Butadien-Kautschuk

Umgebungsbedingungen
Umgebungstemperatur: – 40°C...+85°C
Prozesstemperaturen: – 20°C...+150°C
Prozessdruckbereiche:  – 1 bar ...25 bar
Turn-Down: 30:1
Schutzart
   IP67 EN/IEC 60592  
   IP65 bei Ex-Ausführung