Hit Enter to Search
Pressure safe system Safety first
Pressure safe system Safety first

Pressure safe system Safety first

Designed for gas boilers, the pressure safe system allows a safe discharge of condensates and pressure release valve water.

Inquire now
  • The pump Si-1800 collects condensates and pressure release valve water. A diffuser reduces the pressure of the water discharged in the pump. If a failure occurs, the pump sends a signal to a regulation box. The regulation box then closes the solenoid valve and stops cold water from entering the boiler.

  • Safe installation

  • Preserve the environment

  • Easy and quick installation


Technical details
Max flow rate 500 l/h
Max discharge head 5 m
Mains supply 230V~ 50Hz - 70 W – 0.67A
Protection IP20
Max condensate temperature 65 °C
Max condensate acidity >2.5
Safety switch NC 4 A resistive – 250V
Detection integrated
  • Regulation box including 2 strain reliefs and 4 screws

  • Solenoid valve with 2 m cable bare ends (L,N,G)

  • Diffuser

  • SI1800: centrifugal pump with tank of 2,0 l

  • PVC Tubing : 10 mm ID, 5m long

  • Ø10 to 10 mm (3/8” to 3/8”) straight connector for clear tubing Ø10mm extension

  • 2 bags of 2 screws + 2 rawl plugs

  • Ø int. 15-20-24-32-40 mm (Ø int. 5/8"-3/4"-1"- 1"1/4 -1"½) inlet adaptor for PVC pipe

  • Condensate self-sealing evacuation connector, Ø 10 mm int.

  • Ø10 to 20 mm (3/8” to ¾”) outlet adaptor for rigid tubing Ø20 mm

SOUND LEVELS
at 3,3ft or 1m in application (dBA) ≤ 45.00
Safety standards
CE
EAC
UKCA
ROHS and WEE directives
Compliant