with synthetic thread
With up to 7 probe systems
Fluid Temperature: -40°C ... 150°C
Application description |
The SAT rod probes are used in conjunction with the evaluation units (eg, SRA-100-U0) is used for level detection and level control in conductive liquids.
Depending on the number of bars and evaluation devices used, different measurement tasks such as Overflow, dry run, two-step control, moisture detection, etc. are realized.
Depending on model selected can include the container wall as a mass, to be implemented to 7 switch points. The ground connection erflogt either directly to the container or conducting a probe rod.
In the probe head, an additional module (diode module LBM) for permanent circuit monitoring to be installed.
In the case of a line break between the electrode probe and an appropriate evaluation, the evaluation issue an alert.
Technichal Informations |
Operating pressure: -1 ... 10 bar
Temperature range: -40°C ... +150°C, observe limitations (see operating instructions)
Protection: IP65 EN/IEC 60529
Material connection: POM / PP / PTFE
Probe material: Stahl 1.4404 (AISI316L) bzw. 1.4571 (AISI316Ti) / Hastelloy C22
Isolation probe rod: PA / ETFE bzw. E-CTFE
Gaskets (medium contact): Electrode isolation PA: NBR / Electrode isolation ETFE bzw. E-CTFE: FPM